To reduce or eliminate this boost drop off, you need to input the following values:
RP1 = 050 (5000 RPM)
RP2 = 070 (7000 RPM)
FAC = 100 - [(10 ÷ 15) X 100] = 33
RPM SHIFT LIGHT (RL)
This function allows the user to preset a RPM value at which the display will begin to flash. The RPM will continue to flash until the
engine RPM drops below the preset value. RPM values are entered in multiples of 100, e.g. 5000 RPM = 050. The yellow wire needs to
be connected as per the wiring diagram.
ZERO DISPLAY (ZER)
The E-Boost Street is factory calibrated to read zero at standard atmospheric pressure and temperature. The E-Boost Street is altitude
compensated however a large change in temperature can cause the display to read slightly above or below zero even when there is
zero pressure applied to the E-Boost Street. This function allows you to zero the E-Boost Street if your display reads up to 1 psi (or
equivalent in other units if selected) above or below the original zero point. IMPORTANT! Before using the zero function ensure the
vacuum/pressure line is removed from the back of the unit. This function only allows a reading to be corrected up to plus or minus 1
psi.
FACTORY RESET (RES)
This function performs a factory reset and returns all the settings back to factory default. Be sure that you have written down the settings
that you wish to keep before performing this function.
Boost curve after COR is setup